Firmware Version 3/4.31.37
The following are specific only to the MultiLoad II Mobile product.
Added R/U650 to support reading or writing the GPS database.
Added R140 to support reading the current Latitude/Longitude position.
Added R141 to support reading the current load Latitude/Longitude/Site Index.
Increased transaction count from 200 to 900 transactions and increased the
transaction detail count from 1750 to 3500.
Added new additive W&M configurations R/U104054-W&M Inj Flt Promo Count and
R/U104055-W&M Inj Flt Reset Mode to add W&M promotions to particular additives.
Updated Equipment Configuration Database version to 3.28.12.
Moved placement of NVRAM6 Alibi Log to after NVRAM3.
Updated init code to verify no overlap between NVRAM structures.
09/17/08 3.28.12 WJP
Updated R071-074, Network Address Configurations, to be left justified.
Corrected Alarm log messages to indicate Alarm Count.
Added log message to indicate when Alarm Count is cleared.
Updated Set Factory Defaults to also reset GPS site Database.
Corrected data formatting on Access IDs and Alarm Setup screens.
Added "W&M Access Denied" message on Alarms Setup screens.
Corrected formatting on R140 and R114, GPS data register.
Corrected formatting on R650, GPS Site Database register.
Left justified alarm name in R710-R714.
10/31/08 2.28.12 WJP (Released)
Added buffer clear to prevent old message data from being processed with new
incomplete commands.
Installed default company name from ML Mobile small format ticket.
10/01/08 3.28.13 WJP
Removed legacy FCM trace logging.
Problem with prompt display on view transaction header
Added code to increase the number of supported fcm ports from x to 39 ports.
Added code to increase the number of supported fcm pulse output ports from 1 to 6
ports.
Removed bay.output_pulse_enabled parameter.
Changed bay.output_pulse_fcm_number to output_pulse_fcm_address to include
port.
Changed bay.output_pulses_per_volume to output_pulses_per_volume_thous with 3
implied decimal places to deliver less than one pulse per unit.
Removed preset.output_pulse_enabled parameter.
Changed preset.output_pulse_fcm_number to output_pulse_fcm_address to include
port.
Changed preset.output_pulses_per_volume to output_pulses_per_volume_thous with
3 implied decimal places to deliver less than one pulse per unit.
Added pulse output to the bay diagnostics screen.
Updated R133/U133 to support up to 39 ports.
Removed unused disp_bstat structure from real_time_database.
Increased latest known FCM version to 036.
Per Measurement Canada, whole number totals on ticket must always add up.
Updated Preset and Load whole unit totals to sum component whole totals, and
not fractional parts, per Measurement Canada Requirement.
Updated Component side stream back calculation to difference whole totals, and
not fractional parts, per Measurement Canada Requirement.
Added "*" on ticket total line to indicate if totals are or are not a sum of for-
trade preset values, per Measurement Canada Requirement.
Updated RCU Setup Database version to 3.28.13.