Chapter 16 – Firmware Revision History
443
Firmware Version 3/4.31.37
Updated Real Time Database version to 3.28.13.
Updated Equipment Configuration Database version to 3.28.13.
Updated firmware version to 3.28.13.
10/25/08 3.28.13 WJP
Introduced beta MODBUS register interface.
11/12/08 3.28_13 WJP
Updated Card Reader Logic to support 26-bit, Corporate 1000 formatted cards.
Corporate 1000 reads are returned to the Host system as 0=%04u=00000=%08u=01.
Added ability to build a standalone serial Opto-Iso II tester firmware builds.
Corrected bug with MRCA Request Component Alarms command returning invalid data.
Was using indicated component as preset index.
Updated FCM II factory tests to be event based instead of time based to increase
reliability and speed of test.
Updated FCM II factory tests to support AC expander and Relay expander boards.
12/05/08 3.28_13 WJP
Released full MODBUS protocol and register interface as described in the
MultiLoad Communication Manual.
Updated card reader logic to only accept TWIC card reads if two consecutive reads
indicate only one card is in the reader.
Updated card reader logic to force a card out for approx. 2 seconds when TWIC
cards are swapped.
Add logic to keep current card during power cycle.
12/08/08 3.28_13 WJP (Released to QA)
12/19/08 3.28.13 WJP (Special Build, on ML Mobile Units)
Corrected Pulse Output Port Logic to also accept port 10 on Ver<036 FCMs and I/O
Boards.
Added back in logic to check fcm port assignment conflicts on Pulse Output Ports.
Increased GPS Site Database to 22,000 sites.
Added Default Site List to MLM for Special Build
Updated GPS site search to break up search processing over several calls.
Corrected Database Overlap Checking startup logic.
Updated simulation startup usage to display key mapping and notes.
12/30/08 3.28.14 WJP (released to QA for testing)
Bug Fix:
In certain side stream configurations and conditions (explained below), the
MultiLoad firmware did not correctly calculate one or more Component Net Volumes.
"For Trade" Values and Calculations (Preset Level Gross and Net Volumes) were
not affected.
Only "Not for Trade" or "For Inventory Only" Values and Calculations (Component
Level Net Volumes) were affected.
Problem limited to the previous version of firmware 3.29.11-3.29.13.
Problem limited to configurations where more than one main component shared the
same side stream component. For instance, Reg and Prem components sharing an
ethanol side stream.
Problem limited to recipes that included flowing both of these main components
sequentially in the same blend. For instance, Reg flow with Ethanol side stream,
followed by Prem flow with Ethanol side stream.
Problem limited to the calculation of the Net Component Volumes calculated for
any main components with a common side stream that flow after the first main
component with the common side stream in the blend. For instance, the Premium
component in the previous example.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toptech Systems MultiLoad II SCS and is the answer not in the manual?

Toptech Systems MultiLoad II SCS Specifications

General IconGeneral
BrandToptech Systems
ModelMultiLoad II SCS
CategoryControl Unit
LanguageEnglish

Related product manuals