Chapter 16 – Firmware Revision History
445
Firmware Version 3/4.31.37
Updated PickList routines to support attributed (color selection) of items in the
list.
Moved all W&M Equipment Configurations back under Equipment Configurations.
Moved Temperature, Pressure and Density Calibration functions to the Temperature,
Pressure and Density View Screens.
Moved Temperature Comp and Pressure Comp screens from the W&M Menu to the Views
and Inquiry Menu.
Updated Alarm setup screen to display Alarm configurations under W&M control as
Red and restrict saving changes with W&M switch active.
Added new configuration parameter level of CONDITIONAL to indicate parameters
that can be switched into or out of W&M control.
Added Preset Configuration Parameter "W&M Controlled" that adds W&M write
protection via screen and remote register access (inc. Modbus) to certain
parameters.
Changed level of "Blnd Chk Alarm %", "Blnd Chk Alarm Vol", "Blnd Chk Alarm
Time" to CONDITIONAL.
Added Additive Configuration Parameter "W&M Controlled" that adds W&M write
protection via screen and remote access to certain parameters.
Changed level of "Additive Vol/Inject", "Vol/Inject Cal Factor", "Additive Mtr
K-Factr", "Additive Mtr Factor", "Max Pstn Missed Inj", "Under Add Alrm # Inj",
"Over Add Alrm # Inj", "Check Add Tol Time", "Over Inj Vol" level to CONDITIONAL.
Removed Additive Configuration Parameters "W&M Vol per Inject", "W&M Vol
factor", "W&M Pulses per vol", "W&M Pulse Factor" since no longer needed.
Added Component Configuration Parameter "W&M Recipe Percentage" to enforce
delivery.
Corrected Meter Proving Screen Meter Factor data entry data column alignment.
Updated Equipment Configuration Database version to 3.29.01.
Added printer multidrop capability to Ticket Printing.
Added printer multidrop capability to Alibi Log Printing.
Added ability to multi-drop several MultiLoads on to a single printer using RS232
on COM2. Connections must be as follows:
ML#1 ML#n Serial Printer
RX<-------------RX<--------------------TX
CTS<------------CTS<-------------------DTR
TX------------->TX-------------------->RX
GND-------------GND--------------------GND
DSR-DTR DSR-DTR RTS-CTS-DSR
RTS-DCD<------->RTS-DCD DCD
Added more discrete control of the Transmitter Enable to support having multiple
MultiLoads connected to a single printer.
Dropped monitoring of DSR or DCD for printer status. CTS indicates printer
status.
Added Meter Configuration Parameters "Adaptive Valve Control", "Analog Valve
Control", "4-20mA Increase Step", "4-20mA Decrease Step" to support analog valve
control.
Allow ports 2 & 3 to be used as general IO when Analog Valve control is enabled.
Increased latest known FCM version to 037.
On FCM_TESTER and ISO_TESTER build, allow entry into factory menu.
Updated FCM2 Analog Calibration to ignore COM timeouts when setting calibration
values during test. Was causing test to sometimes restart when FCM was writing to
EPROM and not communicating.
Updated FCM2 Analog RTD/mA Calibration to perform 3 tests then stop.
Updated FCM2 Analog RTD/mA Check to perform 1 test then stop.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toptech Systems MultiLoad II SCS and is the answer not in the manual?

Toptech Systems MultiLoad II SCS Specifications

General IconGeneral
BrandToptech Systems
ModelMultiLoad II SCS
CategoryControl Unit
LanguageEnglish

Related product manuals