Chapter 16 – Firmware Revision History
452
Firmware Version 3/4.31.37
When a default density value is supplied or measured at the meter level, this
density value is accepted as the meter density and is applied to API calculations
on the received meter volumes.
When a default density value is not supplied or measured at the meter level,
a blend weighted density is calculated from the component densities and is accepted
as the meter density and is applied to API calculations on the received meter
volumes.
When a default density value is supplied at the component level, this density
value is accepted as the component density.
When a default density value is not supplied at the component level, a back
calculated density is calculated and is accepted as the component density.
Meter sampled temperature continues to be used for the API calculation on the
received meter volumes.
The meter temperature/density can still be viewed on the Component Status
Screen next to the calculated CTL/CPL values.
The meter temperature/density, gross and calculated net volumes still
appear on the meter line of the printed ticket.
Main component temperature is once again back calculated to keep back end
accounting systems happy.
The component temperature/density, gross and net volumes appear on the
component line of the printed ticket and are marked not for custody transfer.
A host system that queries for real time component level values will be
supplied with the same component temperature/density, gross and net volumes that
appear on the component line of the printed ticket.
A host system that queries for real time component meter level values will
be supplied with the meter temperature/density, gross and net volumes that appear
on the meter line of the printed ticket.
A host system that queries for the transaction archive information will be
supplied with all same meter and component information that is on the printed
ticket.
Setup Component and Meter Temperature/Pressure/Density real time component data.
Setup Component and Meter Gravity/Density get routines.
API routines always use Meter Temperature/Pressure/Density from the real time
component data.
Transaction Component Data always contains component Temperature/Pressure/Density
from the real time component data.
Transaction Meter Data always contains meter Temperature/Pressure/Density from
the real time meter data.
MRS command component data returns component Temperature/Pressure/Density from
the real time component data.
Modbus 4756..5331 register, contains component Temperature/Pressure/Density from
the real time component data.
Component Meter Screen displays the meter Temperature/Pressure/Density from the
real time component data.
Renamed RCU parameter "Print Blend Components" to "Print Blend Details". When
set to 2, all meter records will be archived and printed.
1/5/10 3/4.30.00 WJP
On Simulation builds, send transaction to display.
Move NR3 by 0x1000 bytes to prevent overlap.
Updated MRS and MSS commands to support configuration bits to return meter level
parameters.
Added meter level pressure/temperature/density to the component status screen.
Follow up: Check meter detail print logic on ml_main:2050.
Follow up: Add Modbus registers for meter level gross/net/temp/press/density.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toptech Systems MultiLoad II SCS and is the answer not in the manual?

Toptech Systems MultiLoad II SCS Specifications

General IconGeneral
BrandToptech Systems
ModelMultiLoad II SCS
CategoryControl Unit
LanguageEnglish

Related product manuals