DISASSEMBLY AND REPLACEMENT
4 - 30
Notes:
1. When attaching the wire holder jig [2],
make sure that the wire has not shifted or
become loose.
2. The wire should come out of the slot of
the wire holder jig [2] and be passed
under the jig arm [3].
3. When installing the wire holder jig, be
careful of the orientation.
Fig. 4-78
(4) Remove the tension springs [4] in the front
and rear sides.
(5) Remove the carriage wire [5].
Fig. 4-79
(6) Rotate carriage-2 [6] while trying not to touch
the mirror. Then remove carriage-2 [6].
Notes:
Replace mirror-2 and -3 together with
carriage-2 [6]. Do not remove mirror-2 and -
3.