SETTING / ADJUSTMENT
6 - 24
6.4.2 Density adjustment
The center density and the density variation controlled by density adjustment keys can be adjusted as
follows.
< 05 Adjustment Mode >
Make a test copy and compare the image obtained with the current settings; if necessary, make
adjustment using the following procedure.
<Procedure>
(1) Performs FS-05.
(2) Key in a code and press the [START] button.
(3) Key in an adjustment value.
(To correct the keyed-in value, press the [CLEAR] button.)
(4) Press the [OK] button to store the value. The equipment goes back to the ready state.
(5) Press the [TEST COPY] button and then the [START] button. Then perform test copying.
(6) If the desired image density has not been attained, repeat step (1) to (5).
Original mode
Item to be adjusted Remarks
Text/
Photo
Photo Text User Custom
7114 7116 7115 7134 Manual density mode
center value
The larger the value is, the
darker the image becomes.
Acceptable values: 0 to
255 (Default: 128)
7123 7125 7124 7137 Automatic density
mode
The larger the value is, the
darker the image becomes.
Acceptable values: 0 to 255
(Default: 128)