6
© 2015 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
SETTING / ADJUSTMENT
6 - 13
<Adjustment procedure summarization for A to E>
When the value is 1.
FS-05 [1] ([3] for duplexing) [TEST PRINT]
A: FS-05-4001 (Lower drawer, A3/
LD)
200±0.5 mm (0.15 mm/step)
B: FS-05-4006 (Lower drawer, A3/
LD)
52±0.5 mm (0.0423 mm/step)
Key in the same value for FS-05-4005.
C: FS-05-4526 (Lower drawer, A3/
LD)
200±0.5 mm (0.25 mm/step)
D: FS-05-4058 (Lower drawer, A3/LD), 4059 (Lower drawer, A4/LT), 4060 (PFP, A4/LT),
4063 (LCF, A4/LT), 4061 (Bypass feed, A4/LT), 4062 (Duplexing, A3/LD)
52±0.5 mm (0.1 mm/step
E: FS-05-4019-0 (Lower drawer, A3/
LD), 4019-1 (Lower drawer, A4/
LT))
52±0.5 mm (0.0423 mm/step)