SETTING / ADJUSTMENT
6 - 16
[B] Reproduction ratio adjustment of the primary scanning direction
<Procedure>
(1) Performs FS-05. (05 Adjustment Mode)
(2) Place a ruler on the original glass (along the direction from the rear to the front of the equipment).
(3) Press [FAX] [START] to make a copy at the mode of A3/LD, 100% and the lower drawer (refer
to *).
(4) Measure the distance A from 10 mm to 270 mm of the copied image of the ruler.
(5) Check if the distance A is within the range of 260±0.5 mm.
(6) If not, use the following procedure to change values and repeat the steps (3) to (5) above.
FS-05 Key in the code [4000] [START]
(Key in a value (acceptable values: 0 to 255))
Press the [OK] button (stored in memory).
(“100% A” is displayed.)
* The larger the adjustment value is, the higher the reproduction ratio and the longer the
distance A become.(approx. 0.1 mm/step)