© 2015 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
PREVENTIVE MAINTENANCE (PM)
7 - 25
* a. Do not use alcohol for cleaning the developer unit.
* b. Developer material
After replacing the developer material, be sure to perform the auto-toner adjustment.
P. 6-2 "6.2 Adjustment of Auto-Toner Sensor"
* g. Oil seal
Mixer unit (Shafts of mixers 1, 2 and 3) 6 pcs.
During replacement, coat the oil seal with grease (Alvanian No.2).
(1) Push in a new oil seal parallel to the
mounting hole section of the developer frame
or outside of the holder.
* Pay attention to the direction in which the
oil seal is attached. (See figure on right.)
(2) Apply an even coat of grease to the inside of
the oil seal.
Amount: About two small drops
(3) Wipe off any grease the exudes from the
inside.
Fig. 7-16
Outside
Inside
Developer frame
(Nozzle mixer)
Grease
Oil seal