ERROR CODE AND TROUBLESHOOTING
8 - 76
3
Is the exit motor (rotating
in reverse) working?
(Perform the output check
in the test mode: 03-121/
171): e-STUDIO206L/256/
306 / 207L/257/307
(Perform the output check
in the test mode: 03-124/
174): e-STUDIO356/456/
506 / e-STUDIO357/457/
507
Yes
4
No Check if the connector of the exit motor is
disconnected.
Check if the connector CN431 on the MOT
board is disconnected.
(e-STUDIO206L/256/306 / 207L/257/307)
Check if the connector CN405 on the MOT2
board is disconnected.
(e-STUDIO356/456/506 / 357/457/507)
Check if the connector pins are
disconnected and the harnesses are open
circuited.
Check if the conductor pattern on the LGC
board and MOT board is short circuited or
open circuited. (e-STUDIO206L/256/306 /
207L/257/307)
Check if the conductor pattern on the LGC
board and MOT2 board is short circuited or
open circuited. (e-STUDIO356/456/506 /
357/457/507)
Replace the exit motor.
Replace the MOT board. (e-STUDIO206L/
256/356 / 207L/257/357)
Replace the MOT2 board. (e-STUDIO356/
456/506 / 357/457/507)
Replace the LGC board.
4
ADU Check the rollers in the ADU and the exit
roller of the equipment. Replace them if
they are worn out.
Parts to be replaced Remark
ADU entrance sensor
LGC board
Exit motor
ADU exit sensor
Exit board
LGC board
Rollers in the ADU
Exit roller
Proce
dure
Check item Result Measure