e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A © 2015 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
8 - 200
[CB94] Saddle transport motor abnormality
MJ-1106/1108
[CB95] Saddle Stitch Finisher stacker motor abnormality
MJ-1106/1108
[CBA0] Front saddle stapler home position error
MJ-1106/1108
Classification Error item
Finisher related service call The [CB94] error also occurs when the error [EAB0] or [EF13]
has occurred consecutively for 3 times.
Check item Measures
Transport roller • Is there any mechanical problem when the transport
rollers are rotated?
Saddle transport motor (M16) • Motor check
• Connector check
• Harness check
Saddle control PC board (SDL) • Connector check (CN18)
• Board check
Replace parts Remarks
Saddle transport motor
Saddle control PC board
Classification Error item
Finisher related service call The [CB95] error also occurs when the error [EF16] has
occurred consecutively for 3 times.
Check item Measures
Stacker carrier • Is there any mechanical problem when the stacker carrier
is moved?
Stacker motor (M14) • Motor check
• Connector check
• Harness check
Saddle control PC board (SDL) • Connector check (CN4)
• Board check
Replace parts Remarks
Stacker motor
Saddle control PC board
Classification Error item
Finisher related service call The stapler home position detection is abnormally operated and
finished
Check item Measures
Front saddle stapler clinch unit Harness check
Saddle control PC board (SDL) • Connector check (CN6)
• Board check
Replace parts Remarks
Front saddle stapler clinch unit
Saddle control PC board