E6582233
J-9
10
Torque boost parameters 1
Title
Communicati
on No.
Function Unit
Minimum
setting unit
Panel/Comm
unication
Adjustment range
Default
setting
User
setting
Reference

F400 0400 Auto-tuning - -
0: Auto-tuning disabled
0 6.16
1: Initialization of  (reset to 0)
2: Auto-tuning executed
(after execution: 0)

F401 0401 Slip frequency
gain
% 1/1 0-150 50

F402 0402 Automatic torque
boost value
% 0.1/0.1 0.1-30.0 * 1

F405 0405 Motor rated
capacity
kW 0.01/0.01 0.01-15.00 * 1

F412 0412 Motor specific
coefficient 1
- - - - * 2

F415 0415 Motor rated
current
A 0.1/0.1 0.1-30.0 * 1 6.16

F416 0416 Motor no-load
current
% 1/1 10-90 * 1

F417 0417 Motor rated
speed
min-1 1/1 100-32000 1410

F451 0451 Motor specific
coefficient 1A
- - - - * 2

F458 0458 Motor specific
coefficient 2
- - - - * 2

F459 0459 Load inertia
moment ratio
Time
s
0.1/0.1 0.1-100.0 1.0 6.16

F460 0460 Motor specific
coefficient 3
- - - - * 2

F461 0461 Motor specific
coefficient 4
- - - -

F462 0462 Motor specific
coefficient 5
- - - -

F467 0467 Motor specific
coefficient 6
- - - -
*1: Default setting values vary depending on the capacity. Refer to section 10.4.
*2: Motor specific coefficient parameters are manufacturer setting parameters. Do not change the value of these parameters.
Input/output parameters 2
Title
Communicati
on No.
Function Unit
Minimum
setting unit
Panel/Comm
unication
Adjustment range
Default
setting
User
setting
Reference

F470 0470 VI input bias - 1/1 0-255 128 6.6.4

F471 0471 VI input gain - 1/1 0-255 128