7.3 Reference drive of the machine
After the machine was started up, the machine must be referenced. Go on as
follows for this:
1. After everyone start up of the machine the
safety scanner executes a self check. For this
the protection field of the safety scanner must
be once injured.
The scanner is ready for operating, if the
red LED - control light goes out and the
green LED - control light goes on.
2. Press the button Referencedrive / Automatic
Start., in order to start the reference drive of
the machine.
The Reference point at the rear end of the
machine body is started.
i
NOTE!
After everyone start up of the machine, the off-set bend device
must be referenced!
Reference point
LED control light
Protection field