8.1.4 Clamping pressure adjustment
The clamping pressure of the bend device can be adjusted by turning the pressure
regulation valve at the left side of the machine. Press the button Clamping pressure
adjustment an adjust the pressure by turning the knob on the pressure regulating
valve at the same time. The pressure is shown at the pressure gauge.
WARNING!
Clamping pressure for small adapter shaft: max. 100 bar!
Otherwise the small adapter shaft will be damaged!
Normal adapter shaft
Small adapter shaft
Press button
Pressure gauge
Knob