Operating
8.2.4 Bending in automatic operating sequence
NOTE!
In automatic operation the process can be released over the
Automatic Start button.
If the protective field will be injured, while the machine is in
operating the endangering movement stops the machine
immediately.
Press the button Automatic Start to reset the Safety laser scanner
and the process goes on.
Set the selector switch to position Manual at the control panel.
Make sure if the machine in the starting position! Drive all functions of the
machine in starting position:
- Clamping backward
- Bending backward
- Mandrel forward
- Tool plate backward
- Chuck open