Model 3430 Plus & 3440 Plus
4–9
ASPHALT SITE
This also applies to hardened concrete sites and soil.
NOTE
These directions also apply to taking a backscatter
measurement on soil.
Locate a smooth site on the asphalt.
Fill the voids on open mixes with sand or cement. The gauge
base must rest on the asphalt, not the fill material!
Ensure that the gauge does not rock. To ensure accurate
readings, the gauge base must be completely in contact with the
test material. If the gauge rocks, then find a more suitable test
site. If taking a measurement around a core, the gauge may be
moved a few inches away from the core to level it.
4. USING THE GAUGE