Page #202 background image
TSC AUTO ID Technology Co., Ltd. 190 Copyright 2013 All Rights Reserved.
SET RIBBON
Description
This setting is used to enable/disable ribbon sensor detection. (Thermal Transfer Printing/Thermal
Direct Printing) Printer will detect the presence of a ribbon to determine using either direct thermal or
thermal transfer printing upon printer startup. This setting will NOT be saved in printer memory.
Syntax
SET RIBBON ON/OFF/INSIDE/OUTSIDE
Parameter
Description
ON
Thermal transfer printing
OFF
Thermal direct printing
INSIDE
The ribbon is inside wound. For TTP-384M only. *Since V6.80EZ.
OUTSIDE
The ribbon is outside wound. For TTP-384M only. *Since V6.80EZ.
Example
Sample Code
REM *****Disable ribbon detection sensor for direct thermal printing.
SET RIBBON OFF
SIZE 4,1
GAP 0,0
CLS
TEXT 10,10,"3",0,1,1,"Direct thermal printing."
PRINT 1
REM *****Enable ribbon detection sensor for thermal transfer printing.
SET RIBBON ON
SIZE 4,1
GAP 0,0
CLS
TEXT 10,10,"3",0,1,1,"Thermal transfer printing."
PRINT 1
REM *****For using ink-in ribbon in TTP-384M.
SET RIBBON INSIDE
SIZE 4,1
GAP 0,0
CLS
TEXT 10,10,"3",0,1,1,"TTP-384M is using ink-in ribbon."
PRINT 1
REM *****For using ink-out ribbon in TTP-384M.
SET RIBBON OUTSIDE
SIZE 4,1
GAP 0,0
CLS
TEXT 10,10,"3",0,1,1,"TTP-384M is using ink-out ribbon."
PRINT 1

Table of Contents

Other manuals for TSC TTP-247

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TSC TTP-247 and is the answer not in the manual?

TSC TTP-247 Specifications

General IconGeneral
Print MethodThermal Transfer / Direct Thermal
Resolution203 dpi
Max Print Width4.09" (104 mm)
Processor32-bit RISC CPU
Weight2.5 kg
Max Print Speed7 ips
Memory8 MB SDRAM, 4 MB Flash
InterfaceUSB 2.0, Serial
Ribbon Capacity300 meters
Label Width1" (25.4 mm) ~ 4.33" (110 mm)
Label Thickness0.06 mm ~ 0.19 mm
Power SupplyExternal Universal Switching Power Supply
Operating Temperature5°C to 40°C (41°F to 104°F)
Storage Temperature-4°F to 140°F (-20°C to 60°C)
Operating Humidity25% to 85%, non-condensing
CertificationsCE, FCC, UL, CCC