Must pass through a 50 mesh filter, not form deposits or scale in a water temperature of 60°C.
Total amount of solid material is 250 mg/l or less
* Water quality test is compliant to JIS K0101 or a test conforming to that standard.
* Using cooling water that does not meet these conditions may shorten the service life of the RF Generator or cause malfunctions.
* Avoid using deionized water.
(If deionized water is exposed to the atmosphere, it absorbs atmospheric carbon dioxide which becomes free carbonic acid in the
water and lowers its pH. If the water temperature and the flow rate are high when the pH is low, erosion
*1
and corrosion
*2
may
occur.)
*1: Erosion
A phenomenon where solid particles in the fluid collide with a material. The material is damaged or material is removed from the
surface of the material that was hit.
*2: Corrosion
Rust (green rust) forms due to free carbonic acid that occurs from water and carbon dioxide. This phenomenon degrades the
system's mechanical properties by the formation of rust
* Caution
Always ensure that the water temperature and water volume follow the specifications.