2 EXP. COMPARISON FUNCTIONS
123
EXP. COMPARISON FUNCTIONS
Chapter
2
Double hold and difference-HI/LO limit comparisons
Double Hold HI/LO Limit and Difference-HI/LO Limit comparisons are made, and respective
judgment results are output externally.
When the Comparison Standard is A
:
The HI/LO Limit comparison result and Difference value-HI/LO Limit comparison result of
hold value A are output together.
- Hold value A HI Limit (HI-A) & Difference value-HI Limit (DF-HI)
ON condition:Hold value A > HI-A Limit, or Difference value > Difference value-HI Limit
OFF condition: Hold value A
HI-A Limit, and Difference value
Difference value-HI Limit
- Hold value A LO Limit (LO-A) & Difference value-LO Limit (DF-LO)
ON condition: Hold value A < LO-A Limit, or Difference value < Difference value-LO Limit
OFF condition: Hold value A
LO-A Limit, and Difference value
Difference value-LO Limit
- HI-B Limit (HI-B)
ON condition: Hold value B > HI-B Limit
OFF condition: Hold value B
HI-B Limit
- LO-B Limit (LO-B)
ON condition: Hold value B < LO-B Limit
OFF condition: Hold value B
LO-B Limit
- OK
ON condition: All of HI-A, LO-A, HI-B, LO-B, DF-HI, and DF-LO are OFF.
OFF condition:
Any of HI-A, LO-A, HI-B, LO-B, DF-HI, and DF-LO is ON.
* The Hysteresis setting is not reflected in the Difference-HI/LO Limit comparison operation.
* If the Comparison Timing condition is not met, the comparison result of the value targeted for the
Comparison Timing turns OFF.
* OK is displayed each on the LCD screen as hold value A, and the difference value are OK and
hold value B is OK.
When the Comparison Standard is B
:
The HI/LO Limit comparison result and Difference value-HI/LO Limit comparison result of
hold value B are output together.
- HI-A Limit (HI-A)
ON condition: Hold value A > HI-A Limit
OFF condition: Hold value A
HI-A Limit
- LO-A Limit (LO-A)
ON condition: Hold value A < LO-A Limit
OFF condition: Hold value A
LO-A Limit
FCN-365P024-AU/FCN-360C024-BExternalI/O
A1
COM1 COM2
B1
A2 OUT HI-B WORK0 IN B2
A3 OUT HI-A & DF-HI WORK1 IN B3
A4 OUT OK WORK2 IN B4
A5 OUT LO-A & DF-LO WORK3(LOCK) IN B5
A6 OUT LO-B T/H IN B6
A7
COM1 COM2
B7
A8 OUT HOLD END(H/E) SECTION IN B8
A9 OUT RUN D/Z IN B9
A10 OUT EVENT GRAPH TRIG IN B10
A11 OUT SIF CAL0 IN B11
A12 OUT SIF CAL1 IN B12
- External I/O pin assignments for Comparison Standard A