EasyManua.ls Logo

Unipulse F372A - 4 EXP. OPERATION FUNCTIONS; 4-1. CR Characteristic (Primary) Digital Filter

Unipulse F372A
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
130
3 EXP. GRAPH FUNCTION
130
EXP. GRAPH FUNCTION
Chapter
3
3-1. Graph Pre Trigger Display Function
A graph is plotted by tracking back the time by the percentage set for Pre Trigger Display.
Pre trigger display setting
ON / OFF Initial value: OFF
How to set
When this setting is ON, the Pre Trigger Value setting is displayed in the graph setting menu to
allow adjustment of the amount of Pre Trigger Display.
Pre trigger value
0 to 20 Initial value: 0
How to set
3 EXP. GRAPH FUNCTION
Absence of Pre Trigger Display Presence of Pre Trigger Display (20%)
* The Pre Trigger Value can be set in the range of 0 to 20%.
* Even if the Pre Trigger Value is set, the graph plotting time is fixed, in which
plotting is performed from the head of the Pre Trigger Value: therefore, the time
of plotting from its start becomes short by the Pre Trigger Value.
* The Pre Trigger Value can be set on each piece of work.
* No hold point is marked in the Pre Trigger Display area.
A graph is plotted by
tracking back the time.
SET. Exp. Graph Set. Page 1
→→
Exp. Setting
SET. Graph Setting Page 2
→→
Work Setting

Table of Contents

Related product manuals