5 SETTING OF FUNCTIONS
59
SETTING OF FUNCTIONS
Chapter
5
Level (only Peak and Valley)
By this method, the hold detection section is from the point in time when the indicated value
crosses the Hold Start Level until it crosses the Hold Stop Level. The hold is released by turning on
the T/H signal as a reset signal. The H/E output signal is on between the instant when the hold
section time ends and the instant when the T/H signal is turned on.
However, there are limitations that the Hold Start Level should be passed HI and the Hold Stop
level be passed LO in peak hold, while the Hold Start Level should be passed LO and the Hold Stop
level be passed HI in valley hold.
(Example) Level specified section peak hold
t3: A minimum reset signal width
required for releasing the hold
1.0ms (min.)
5-12.Multi-hold Function
By this function, up to 16 types of hold, graph and comparison set values can be stored and selected
with external switching signals of WORK0 - WORK3.
Normally, if there is no entry for WORK0 - WORK3, the set value of WORK00 is selected, but when
WORK0 - WORK3 are in the following conditions, the set value of each
Measurement work
is selected.
(0: open, 1: short)
WORK3 WORK2 WORK1 WORK0 Measurement work
00 00 WORK00
00 01 WORK01
00 10 WORK02
00 11 WORK03
01 00 WORK04
01 01 WORK05
01 10 WORK06
01 11 WORK07
10 00 WORK08
10 01 WORK09
10 10 WORK10
10 11 WORK11
11 00 WORK12
11 01 WORK13
11 10 WORK14
11 11 WORK15
Indicated Value
t3
Sensor Input Value
Detection
t
+
T/H
H/E
Hold Section
Fixed
OFF
ON
OFF
ON
OFF
ON
ON
Blink ON
OFF ON
OFF
OFF
OFF
HOLD
Status Display
PEAK*
Status Display
passed HI
passed LO
Hold Start Level
Hold Stop Level
HI-LO Limit
Judging Output
*The status display changes depending on the hold mode.