EasyManua.ls Logo

Unipulse F372A - About Changing of the Setting Work; Work Copy

Unipulse F372A
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
60
5 SETTING OF FUNCTIONS
60
SETTING OF FUNCTIONS
Chapter
5
About changing of the setting work
When changing the hold or comparison set value of each work, set the Work No. with the Work
change key on the mode selection screen, and change the set value.
How to set
1) Select the setting Work on the Work setting screen.
2) Then, enter each set value in a likewise manner.
Work copy
Work can be copied. Press on the Work
Setting screen. Set Source(0-15) and Copy(0-15).
Data to be copied are all set values of Comparison
setting, Hold setting, and Graph setting.
I/O terminal block
B1 or
B7 COM2
B2 WORK0
B3 WORK1
B4 WORK2
B5
WORK3
*
CAUTION
It takes 15msec at the maximum for the changed work No.
to become effective. During this section, which work is
measured is undefined.
Also, when the work is switched, the hold and graph
functions are reset under the after-switching work
conditions irrespective of the previous operation.
* If Measurement Work Selection is not set to External Input,
measurement work cannot be specified by external input.
Also, if the B5 Function Selection setting is not WORK3, the B5 pin
does not function as WORK3.
For making the settings of all Works equal, set the Work No. to “All”.
The value set with “All” is set for all WORK00 - WORK15.
CAUTION
The setting work change key is not for specifying the measurement work.
Designate Measurement Work(s) with external selector signals WORK0 - WORK3.