81
6 OPTION
81
OPTION
Chapter
6
6-3. External I/O (Source type (ISC) option)
The source type external input/output signal is an option which can be changed external input/
output signal of F372A to source type. (The standard is sink type.)
The connection of external input/output signal is the minus common.
How to connect external outputSource type
- Equivalent circuit
How to connect external input
(minus common connection of voltage input type)
- Equivalent circuit
Vceo=30V(max)
COM1
Output
Ic=30mA(max)
Input
COM
F372A
Source type
PLC, etc.
Minus common connection
A1,A7
A2 A6
A8 A10
DC24V
COM
Output
Ic= app.5mA
Input
COM2
PLC, etc.
Source type
F372A
Minus common connection
B1,B7
B2 B6
B8 B12
DC24V
CAUTION
Connect elements that can pass Ic=5mA or more.
The leak current of the elements connected should be 400μA or less.
External power supply (DC24V) is needed since F372A does not have
the power supply