EasyManua.ls Logo

Unipulse F372A - Equivalent Circuit; Signal Timing

Unipulse F372A
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
77
6 OPTION
77
OPTION
Chapter
6
Equivalent circuit
-Output The signal output circuit is operated through a TTL open collector.
-Input
Signal timing
-STAB This signal turns on at the same time as BCD data when stability is detected by Motion
Detect (MD). This signal is not output when the output data is a real time
value.("Motion Detect (MD)"on page 41)
-OVER This signal is output at the time of a sensor error or ±OVER.
F372A
Inside
Vcc
+5V
COM
Vext
Vceo=30V(max)
Ic =30mA (max)
Output data Negative Positive
0OFFON
1ONOFF
Output data Negative Positive
0
HL
1
LH
Through logic switching (B14)
Outside
Internal transistor status Output pin level
Vcc
F372A
Inside
IC=
Approx.
COM
Switch
Transistor
+5V
TTL open collector output
Open OFF
Short ON
Outside
6mA
(ON when IN is HI)
CAUTION
-
Do not apply external voltage to the signal input circuit.
- The external element is required to withstand Ic=10mA.
- Leakage from the external element is required to be 30μA or below.
BCDdata
STAB
OVER
0
1
0
1

Table of Contents