EasyManua.ls Logo

Unipulse F372A - Page 145

Unipulse F372A
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
144
8 SUPPLEMENTS
144
SUPPLEMENTS
Chapter
8
Expansion 3 -Double holdBefore value comparison-
Note) When double hold is on: object value of before value comparison is selected by "11: The comparison standard".
Expansion 4 -Double holdRelative value comparison-
Expansion 5 -Double holdBefore value comparisonRelative value comparison-
*2) A and B counterchange according to the comparison standard setting.
1
1 HI-A Limit 6000
99999 to 99999
S
101 R/W
2 Lo-A Limit 4000
99999 to 99999
S
102 R/W
3 HI-B Limit 8000
99999 to 99999
S
103 R/W
4 Lo-B Limit 2000
99999 to 99999
S
104 R/W
5 Hysteresis 0
9999 to 9999
S
105 R/W
2
6 Alarm HI Limit 99999
99999 to 99999
S
106 R/W
7 Alarm LO Limit
99999 99999 to 99999
S
107 R/W
8 Near Zero 100 0 to 99999 S
108 R/W
9 Comparison Timing A 0: ALL 0: ALL 1: MD 2: NZ 3: MD+NZ 4: HOLD S
109 R/W
10 Comparison Timing B 0: ALL 0: ALL 1: MD 2: NZ 3: MD+NZ 4: HOLD S
115 R/W
3
11 Comparison Standard 0:Hold A
0:Hold A
 
1:
Hold
B
S
116 R/W
12 Before Value Regulation 99999 1 to 99999 S
113 R/W
13 Before Value 0
99999 to 99999
S
114 R/W
14 Difference-HI Limit 1000
99999 to 99999
S
111 R/W
15 Difference-LO Limit
1000 99999 to 99999
S
112 R/W
1
1
HI-A Limit (HI-B Limit) *2
6000
99999 to 99999
S
101/
103
R/W
2
Lo-A Limit (Lo-B Limit) *2
4000
99999 to 99999
S
102/
104
R/W
3 Relative-HI Limit 1000
99999 to 99999
S
117 R/W
4 Relative-LO Limit
1000 99999 to 99999
S
118 R/W
5Hysteresis 0
9999 to 9999
S
105 R/W
2
6 Alarm HI Limit 99999
99999 to 99999
S
106 R/W
7 Alarm LO Limit
99999 99999 to 99999
S
107 R/W
8 Near Zero 100 0 to 99999 S
108 R/W
9
Comparison Timing A
(Comparison Timing B) *2
0: ALL 0: ALL 1: MD 2: NZ 3: MD+NZ 4: HOLD S
109/
115
R/W
10 Relative Comparison Timing 0: ALL 0: ALL 1: MD 2: NZ 3: MD+NZ 4: HOLD S
115/
109
R/W
3
11 Comparison Standard 0:Hold A
0:Hold A
 
1:
Hold
B
S
116 R/W
12
13
14
15
1
1
HI-A Limit (HI-B Limit) *2
6000
99999 to 99999
S
101/
103
R/W
2
Lo-A Limit (Lo-B Limit) *2
4000
99999 to 99999
S
102/
104
R/W
3 Relative-HI Limit 1000
99999 to 99999
S
117 R/W
4 Relative-LO Limit
1000 99999 to 99999
S
118 R/W
5Hysteresis 0
9999 to 9999
S
105 R/W
2
6 Alarm HI Limit 99999
99999 to 99999
S
106 R/W
7 Alarm LO Limit
99999 99999 to 99999
S
107 R/W
8 Near Zero 100 0 to 99999 S
108 R/W
9
Comparison Timing A
(Comparison Timing B) *2
0: ALL 0: ALL 1: MD 2: NZ 3: MD+NZ 4: HOLD S
109/
115
R/W
10 Relative Comparison Timing 0: ALL 0: ALL 1: MD 2: NZ 3: MD+NZ 4: HOLD S
115/
109
R/W
3
11 Comparison Standard 0:Hold A
0:Hold A
 
1:
Hold
B
S
116 R/W
12 Before Value Regulation 99999 1 to 99999 S
113 R/W
13 Before Value 0
99999 to 99999
S
114 R/W
14 Difference-HI Limit 1000
99999 to 99999
S
111 R/W
15 Difference-LO Limit
1000 99999 to 99999
S
112 R/W

Table of Contents

Related product manuals