EasyManua.ls Logo

UniVer TC - TCXEC and TEXEC Modules - EtherCAT

Default Icon
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rev.B15
Pg. 10 di 80
TCxEC and TExEC modules - EtherCAT
Fieldbus data EtherCAT
Connectors X1 IN e X2 OUT Circular M12 Female 4 pin D code
10Base-T/100Base-TX, Half/Full Duplex
Auto Crossover Function; Auto-Negotiation
System LED
ON/DIAG Green/Red
RUN/RDY Green/Red
Auxiliary LEDs
Out Supply Green
BUS LED ECAT RUN Green
ECAT ERR Red
L/A IN Green
L/A OUT Green
Electrical data
Connector power supply Circular M12 male 4 pin A code
Logic voltage / digital inputs (VLS24) 24 Vdc ± 15%
Nominal power 150mA (TCxEC)
Maximal power for digital inputs 1,5A @ 20°C overload protection
Manifolds/outputs voltage (VA24) 24 Vdc -10% +15% (valves limit)
Maximal power for all outputs (VA24) 2,5A max - overload protection
Manageable outputs for valve manifolds 24 max coils - (12 bistable valves - 1,5A for 12 coils)
Manageable auxiliary digital outputs 64 digital outputs (88 total outputs with 24 manifold coils)
Manageable auxiliary digital inputs 64 digital inputs
Environmental conditions
Weight TCxEC/TExEC 290g/260g
Module overall dimensions 100x123x75 mm / 90x123x75 mm
Protection degree IP 65 (with connectors) IEC 60529
Relative humidity 5 to 85% IEC 60068-2-30
Operating temperature
5°C
÷
50°C
IEC 60068-2-1
Storage temperature
-25°C
÷
80°C
IEC 60068-2-2
Vibrations 5g tested 10-500Hz IEC 60068-2-6
Shock 22g IEC 60068-2-27

Table of Contents