EasyManua.ls Logo

UniVer TC - Network Address Configuration: Profinet, EtherNet;IP, EtherCAT

Default Icon
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rev.B15
Pg. 23 di 80
How to set Profinet, EtherNet/IP, EtherCAT network address
Profinet
The device has the following factory settings:
Name: txxpnxxxxx
IP Address: 171.16.0.10
IP Mask: 255.255.255.0
Gateway: 0.0.0.0
EtherNet/IP
The device has the following factory settings:
IP Address: 171.16.0.250
IP Mask: 255.255.255.0
Gateway: 0.0.0.0
Bootp: Disabled
DHCP: Disabled
DNS: Disabled
To configure these devices, it is possible to use the master software (i.e. TIA Portal for
Profinet, BootP per Ethernet/IP, TwinCAT per EtherCAT, ecc) or the “Ethernet/IP Device
Configuration” software available on our website (only for Profinet or Ethernet/IP).
Here below an example on how to use the “Ethernet Device Configuration” to set the IP address.
Be sure that in the “Options” “Protocols”, both “NetIdent” and “DCP” are ticked.