BERT - Control Setup (Manual) BERT - Device Discovery
TX Discover Feature
- If the local and remote test sets are on the same IP subnet, the TX Discover feature can be used
- Automatically discover the far-end test unit by pressing the Discover button
- Once discovered, select the remote unit and send a loop up command
- No manual configuration of the IP address is needed, since these are populated automatically
Go back to top Go back to ToC
Asymmetric Mode: No configuration is necessary.
BERT - Control Setup (Asymmetric)
TX130M+_e-manual_D07-00-051P_RevD00