5. PROGRAMMING
32 D-303222 PowerMaster-10/30 G2 Installer's Guide
- Configuring New Devices
To review or change the Location (name) setting, press the button, otherwise scroll to the next option.
To change the Location name, enter the menu and select the name from the "Location List" below. You can
assign additional custom names using the "06.CUSTOM NAMES" option in the Installer menu. See section 5.8.
Note: As a shortcut, press the 2 digit serial No. of the Location shown in the Location List above, which takes
you directly to its menu.
To review or change the Zone Type setting, press the button, otherwise scroll to the next option.
The zone type determines how the system handles signals sent from the device. Press and select a
suitable zone type. The list of available Zone Types and the explanation for each zone type is provided below.
Note: As a shortcut, press the 2 digit serial No. of the Zone Type shown in the Location List above, which
takes you directly to its menu.
All zones are set to Chime OFF by default. To configure the device to cause the panel to sound (when disarmed)
a Chime melody when tripped, press the button, otherwise scroll to the next option.
Note: For UL Listed Product, the Chime setting must be set to “Chime ON”.
Select between "Chime OFF", "melody-chime" and "zone name-chime"
1
. In "melody chime" the control
panel sounds a chime melody when the sensor is tripped. In "zone name-chime" the control panel sounds the
zone name when the sensor is tripped. The chime operates during the Disarm mode only.
Partitions setting:
Note: The "PARTITIONS" menu appears only if Partitions is enabled in the control panel (see section 5.14).
When entering the menu, the display shows the default Partition selection (marked with ).
Use the keypad keys , , to change the status of the partitions P1, P2 & P3, respectively.
To review or change the Device Configuration (settings), press the button, otherwise scroll to the next
option – see [5].
To configure the device parameters, refer to its corresponding device datasheet in the device Installation
Instructions. The defaults of the device parameters can be also configured as explained in section 5.4.6.
After completing the configuration of the device, the wizard brings you to the "Next Step" menu with the
following 3 options:
"NEXT Device" to enroll the next device.
"MODIFY Same Dev." reverts to Step 1 (i.e. "LOCATION") to allow you to perform additional changes to the
device, if needed.
"EXIT Enrollment" exits the enrollment procedure and returns to Step 1 bringing you back to the
"02:ZONES/DEVICES" menu.
Refers to PowerMaster-30 G2 only