EasyManuals Logo

Visonic POWERMASTER-10 - INSTALLER GUIDE User Manual

Visonic POWERMASTER-10 - INSTALLER GUIDE
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #35 background imageLoading...
Page #35 background image
34 D-302756
7.
Here you enter the IP address of the IP receiver that is located in the 1
st
Monitoring Station.
8.
Enter the IP address of the first IP receiver (for further details see the
table at the end of this section).
9.
10.
Here you enter the IP address of the IP receiver that is located in the 2
nd
Monitoring Station.
11.
Enter the IP address of the second IP receiver (for further details see the
table at the end of this section).
12.
13.
Here you enter the telephone number of the SMS receiver that is located
in the 1
st
Monitoring Station.
14.
Enter the telephone number of the first SMS receiver (for further details
see the table at the end of this section).
15.
16.
Here you enter the telephone number of the SMS receiver that is located
in the 2
nd
Monitoring Station.
17.
Enter the telephone number of the second SMS receiver (for further
details see the table at the end of this section).
18.
You can now press the button to take you to the "
PSTN RPRT
FORMAT
" menu, or press the button to take you to "
<OK> TO
EXIT
".
Compatible Monitoring Station receivers are:
Osborne-Hoffman model 2000, Ademco Model 685, FBII Model CP220, Radionics Model D6500, Sur-
Gard Model SG-MLR2-DG and Silent Knight Model 9500.
IMPORTANT: In telephone number locations and account number locations, you may be required to enter
hexadecimal digits. In telephone number locations, these digits are used as codes to control the dialer:
SMS RCVR2
SMS RCVR2
SMS RCVR1
SMS RCVR1
IP RCVR 2
000.000.000.000
IP RCVR 2
IP RCVR 1
IP RCVR 1
000.000.000.000
PSTN/GSM RCVR 2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Visonic POWERMASTER-10 - INSTALLER GUIDE and is the answer not in the manual?

Visonic POWERMASTER-10 - INSTALLER GUIDE Specifications

General IconGeneral
CategorySecurity System
ModelPOWERMASTER-10
Wireless ProtocolPowerG
Backup BatteryYes
User CodesUp to 48 user codes
TypeWireless Alarm System
Partitions3
CommunicationGSM
Wireless Frequency868 MHz
KeypadsUp to 8 keypads
Event Log1000 events
Power SupplyExternal power supply
Backup Battery Voltage7.2V
Operating Temperature-10°C to +50°C
Humidity85% non-condensing
ZonesUp to 30 wireless zones