EasyManua.ls Logo

Wacker Neuson RD40

Wacker Neuson RD40
234 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance
Hydraulic oil supply
BA RD40_RD45 en 00
143
4.04.02 Changing the hydraulic oil and ventilation filter
$ Only lubricants with this symbol are permitted ("Technical data",
page 162 onwards).
Variant 1
Standard version
2
3
1
Variant 2
Vandalism-proof version
2
4
Switch off diesel engine and remove ignition key.
Allow machine to cool down less than 30 °C (86 °F).
Unscrew oil drain screw [3] down on the oil tank and discharge the
used oil drain into a provided receptacle.
Remove the ventilation filter [2] (for variant 2, use a special key [4] to
loosen it before) and replace it with a new filter.
Screw in oil drain screw [3] and tighten.
Fill up specified oil through filling spout [2].
Correct oil level: Centre of sight glass [1].
Tighten ventilation filter [2].
Start the diesel engine.
Actuate drive lever with low engine speed until the transmission
activates.

Table of Contents

Related product manuals