Maintenance
Water sprinkling
BA RD40_RD45 en 00
155
4.08 Water sprinkling
NOTICE
Corrosion and frost!
Material damage to sprinkler installations due to corrosion and frost.
While the machine is going to be parked for an extended period of time
and/or in case of danger of freezing:
Empty and clean the water sprinkling unit/additive sprinkling
system.
Remove and clean the sprinkler nozzles.
Carry out antifreeze work, if available.
4.08.01 Check the water-sprinkling tank fill level
The tank for the water sprinkling system is integrated into the control
stand.
Add an antifreeze solution when outdoor temperatures are below the
freezing point of water. Make sure you use the mixing ratio specified by
the manufacturer.
Top up with water in good time.
2
1
Read the fill level of the water tank at the float in the sight glass [1].
If it needs to be topped up, open the tank cover [2] and fill the water
tank with water.
Lock the tank cover [2] again.
4.08.02 Sprinkler nozzle inspection
Check that an even sprinkling pattern is obtained on the roller
drums/tyres.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson RD40 and is the answer not in the manual?

Wacker Neuson RD40 Specifications

General IconGeneral
BrandWacker Neuson
ModelRD40
CategoryConstruction Equipment
LanguageEnglish

Related product manuals