Code no. Component Possible cause
100 Driving light Open line, short-circuit
102 Rotating beacon Open line, short-circuit
103 Additive sprinkling pump Open line, short-circuit
104 Drum edge lighting Open line, short-circuit
105 Reversing light Open line, short-circuit
106 Water sprinkling pump Open line, short-circuit
107 Signal horn Open line, short-circuit
108 Auto. stop fault Open line, short-circuit
109 Regeneration fault Open line, short-circuit
110 Working spotlight, left Open line, short-circuit
111 Working spotlight, right Open line, short-circuit
112 Stop solenoid Open line, short-circuit
113 Starter relay Open line, short-circuit
114 Rear solenoid valve vibration Open line, short-circuit
115 Amplitude preselection Open line, short-circuit
116 Alert buzzer Open line, short-circuit
117 Drive pump Open line, short-circuit
118 Left turn signal Open line, short-circuit
119 Left parking light Open line, short-circuit
120 Lower KAG solenoid valve Open line, short-circuit
121 Raise KAG solenoid valve Open line, short-circuit
122 Parking brake Open line, short-circuit
123 Solenoid valve vibration, front Open line, short-circuit
124 Reversing alarm Open line, short-circuit
125 All-wheel lock Open line, short-circuit
126 Right parking light Open line, short-circuit
127 Right turn signal Open line, short-circuit
128 Water sprinkling Internal plausibility error
129 Solenoid valve vibration front or rear Internal plausibility error
160 Machine CAN BUS Internal plausibility error
161 Internal memory Internal plausibility error
162 Diesel engine temperature Diesel engine temperature fault
163 Engine CAN BUS Engine CAN BUS fault
164 Hydraulic oil pressure or temperature sensor Short-circuit, mechanical defect
165 Drive lever Implausible signal
166 Starting conditions Implausible signal
600 HCM Fault

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson RD40 and is the answer not in the manual?

Wacker Neuson RD40 Specifications

General IconGeneral
BrandWacker Neuson
ModelRD40
CategoryConstruction Equipment
LanguageEnglish

Related product manuals