Fig 6-13 MCP page - Fuel mode control - Transfer status information
Tab 6-4 MCP page - Fuel mode control - Transfer status information
Item Function Effect
001 TRANSFER button Switches to the transfer mode, green LED turns on
002 Indication field Shows the data for transfer status
Shows: Gas Request, FGSS Ready, FGSS Not Ready, iGPR
Leak Test OK, iGPR Leak Test Fail, iGPR Flushing OK, iGPR
Flushing Fail, iGPR Pressure OK, iGPR Pressure Fail, Transfer
Prep. OK
X72-B
AA00-4618-06AAA-043B-A
Operation Manual MCP page - FUEL MODE CONTROL - Option for WiCE
Winterthur Gas & Diesel Ltd.
- 251 - Issue 003 2021-12