EasyManua.ls Logo

WinGD X72-B - Cooling Water System

Default Icon
526 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.2 Cooling water system
The cooling water system supplies the items that follow with cooling water:
Cylinder liner
Cylinder cover
Exhaust valve cages
Scavenge air cooler (SAC).
For the schematic diagrams, refer to section 13.1 Schematic diagrams - general.
The cooling water system has the engine connections as interface to the plant as follows (in Figure
4-2 marked with a circle):
Connection 02 (cylinder cooling water inlet)
Connection 05 (cylinder liner cooling water inlet (bypass cooling water system)) (optional)
Connection 03 (cylinder cooling water outlet)
Connection 05 (cylinder cooling water drain outlet)
Connection 07 (SAC LT-cooling water inlet) (not shown)
Connection 08 (SAC LT-cooling water outlet) (not shown).
If the supply at the engine connection 02 is installed, the cylinder liner is supplied with cooling
water at a higher temperature than the cylinder cover.
The cooling water system has the parts that follow:
Automatic venting unit
The automatic venting unit (001) constantly releases unwanted air from the cooling water.
Shut-off valve
The shut-off valve (002) and (003) constantly releases cooling water to the automatic
venting unit (001) to release unwanted air from the cooling water.
Drain valve
The drain valve (004) is used to drain the cooling water.
X72-B
AA00-0000-00AAA-043A-A
Operation Manual Cooling water system
Winterthur Gas & Diesel Ltd.
- 74 - Issue 003 2021-12

Table of Contents

Related product manuals