PROCEDURE
1 Decrease the engine power to approximately 25 to 85%.
2 Clean the compressor of the turbocharger, refer to the documentation of the manufacturer.
3 Clean the turbine of the turbocharger, refer to the documentation of the manufacturer.
CLOSE UP
None
X72-B
AA00-6500-00AAA-200A-A
Operation Manual Clean the turbocharger during operation
Winterthur Gas & Diesel Ltd.
- 373 - Issue 003 2021-12