Tab 10-47 Condensation flow at a water separator is too high
Indication Possible cause Procedure
LS4071-nnA The filter in the return pipe is
clogged
Clean the filter.
The opening in the return pipe is
clogged
Clean the return pipe.
There are leaks in the SAC
Find the cause and repair the fault.
Tab 10-48 Condensation flow upstream of a water separator is too high
Indication Possible cause Procedure
LS4075-nnA The filter in the return pipe is
clogged
Clean the filter.
The opening in the return pipe is
clogged
Clean the return pipe.
There are leaks in the SAC
Find the cause and repair the fault.
Tab 10-49 Scavenge air temperature in the piston underside is too high
Indication Possible cause Procedure
TE4081-nnA There is fire in the piston underside
Refer to section 2.4 Fire-fighting in the scav-
enge air space.
A piston ring is defective
As a temporary procedure, decrease the
load and cut out the injection of the related
cylinder.
As a temporary procedure, increase the
feed rate of the cylinder oil of the related
cylinder.
Repair or replace the piston rings.
The engine has too much load
Decrease the fuel injection quantity.
Tab 10-50 Starting air supply pressure is too low
Indication Possible cause Procedure
PT4301-nnC The starting air supply system is
defective
Find the cause and repair the fault.
Tab 10-51 Pressure of the air spring air supply is too high
Indication Possible cause Procedure
PT4341A There is an incorrect setting of the
control air supply
Set the control air supply to the correct val-
ue.