PROCEDURE
1 Isolate the defective cylinder from the cooling water system.
2 Make sure that there is no air spring air pressure.
3 Lock the exhaust valve in the open position as follows:
3.1 Remove the damper from the top housing (001).
3.2 Make sure that you do not lose the shim(s) (004).
NOTE: The shim(s) must stay in position when the pressure element is installed.
3.3 Apply a thin layer of oil to the thread of the pressure element (003).
3.4 Install the pressure element (003).
4 Cut out the defective cylinder from the injection, refer to section 10.7 Temporary cut out a
defective injection valve.
5 Disconnect the electrical connection to the related exhaust valve control unit (VCU).
6 Disconnect the control signal connection from the related starting air valve.
7 Repair the fault as soon as possible, refer to the Maintenance Manual.
CLOSE UP
The engine can be started and operated at decreased load, refer to section 8.3 Start the
engine - general
X72-B
AA00-0000-00AAA-662B-A
Operation Manual Temporary isolate a cylinder with cooling water leakage
Winterthur Gas & Diesel Ltd.
- 427 - Issue 003 2021-12