PROCEDURE
1 If an oil mist detector activates an alarm, do as follows:
1.1 Decrease immediately the engine speed (power).
1.2 Stop the engine if possible.
1.3 Let the engine temperature decrease for a minimum of 20 minutes.
1.4 Find the cause and repair the fault.
NOTE: If no fire-extinguishing system is installed or not in use, a portable fire
extinguisher must be kept ready when the crankcase doors are opened.
CLOSE UP
None
X72-B
AA00-0000-00AAA-012D-A
Operation Manual Prevent explosions in the crankcase
Winterthur Gas & Diesel Ltd.
- 57 - Issue 003 2021-12