PROCEDURE
1 Open the relief valve with the spindle (001, Figure 7-55).
2 Disconnect the electrical cable from the connector.
3 Remove the two screws (002).
4 Remove the relief valve from the cylinder cover (003).
5 Remove and discard the O-rings.
Fig 7-55 Relief valve combustion chamber
005
001
003
002
004
6 If necessary remove the sensor (004).
6.1 Remove the holder (005) and the sensor (004) from the tip of the relief valve.
6.2 Remove the holder (005) from the sensor (004).
6.3 Remove the sensor (004) with the cable from the relief valve.