ELECTRICAL SYSTEM
L3301, L3901, L4701, WSM
9-S17
Checking Slow-Blow Fuses
1. The slow-blow fuses are intended to protect the electrical
cabling. If any of them has blown out, be sure to pinpoint the
cause. Never use any substitute, use only a KUBOTA genuine
part.
[L3301/L3901]
[L4701]
9Y1211012ELS0015US0
Checking Ground Cable
1. Check the whether the ground cables (1) are connected
securely to the tractor chassis.
2. If the ground cables are broken or disconnected, replace it.
9Y1211012ELS0016US0
No. Capacity (A) Protected circuit
(1) 40 Load
(2) 50 Battery
(3) 40 Heater (Oil separator) (if equipped)
No. Capacity (A) Protected circuit
(1) 40 Load
(2) 60 Battery
(3) 40 Heater (Oil separator) (if equipped)
[A] L3301/L3901 [B] L4701
(1) Ground Cable [A] Manual Transmission Model
[B] HST Model