7/98
General Procedures and Information 5-26 Xerox DocuPrint P8e Service Manual
4 Turn the printer upside down and remove all the screws securing the shield cover. Remove the
shield cover.
5 If you are replacing a SIMM, push out on the metal clips at each end of the SIMM connector and
pull the SIMM toward you and lift it out.
6 Hold the SIMM with the connection points pointing toward the control board and insert the SIMM
all the way into the connector at a 45 degree angle.
7 Push the SIMM away from you until it snaps into place.
Make sure both metal clips on the connector are fastened and the two pins on the connector are
pushed through the holes on the SIMM.
8 Replace the shield cover.
9 Turn the printer back over and replace the image cartridge.
sm5_010
sm5_008
sm5_009
Step 6
Step 7