122 www.xilinx.com ChipScope Pro Software and Cores User Guide
UG029 (v14.3) October 16, 2012
Chapter 4: Using the ChipScope Pro Analyzer
IBERT_A7GTP > Import/Export Wizard or click the Import/Export Wizard button in the
toolbar.
Use the first screen of the wizard to choose the source of the MGT settings, either MGT or
File. If MGT is selected, choose among the available MGTs in the combo box. For File, click
Browse and navigate to the settings file.
The second wizard screen is the destination screen. Any combination of the MGTs in the
IBERT design and a file is available. If File is enabled, click Browse to specify the file
destination.
The third screen is the confirmation screen, summarizing the source and destination(s) for
the settings. Click Apply to execute the import or export. This operation cannot be undone.
Reset All
To reset all the channels in the IBERT core, select IBERT_A7GTP > Reset All or click the
Reset All button in the toolbar.
JTAG Scan Rate and Scan Now
Use the JTAG Scan Rate toolbar and IBERT_A7GTP > JTAG Scan Rate menu options to
select how frequently the ChipScope Pro Analyzer tool queries the IBERT core for status
information. The default is 1s between queries, but it can be set to 250 ms, 500 ms, 1s, 2s, 5s,
or Manual Scan. When Manual Scan is selected, use IBERT_A7GTP > Scan Now or the
Scan Now (or S!) toolbar button to query the IBERT core.
IBERT Console Window for 7 Series FPGA GTZ Transceivers
To open the console for a ChipScope Pro IBERT core for Virtex-7 FPGA GTZ transceivers,
select Window > New Unit Windows and the core desired. A dialog box displays for that
core, and you can select the IBERT V7 GTZ Console.
The same operation can be achieved by double-clicking the IBERT V7 GTZ Console leaf
node in the project tree, or by right-clicking the IBERT V7 GTZ Console leaf node and
selecting Open IBERT V7 GTZ Console.
The IBERT Console for Virtex-7 GTZ transceivers is composed of the following:
• MGT/BERT Settings Panel
• DRP Settings Panel
• Port Settings Panel
• RX Margin Analysis Panel
• IBERT Virtex-7 FPGA GTZ Transceiver Toolbar and Menu Options
MGT/BERT Settings Panel
The MGT/BERT Settings panel contains a table that is made up of one or more vertical
columns and horizontal rows. Each column represents a specific active GTZ transceiver.
Each row represents a specific control or status setting.
MGT Settings
The MGT Alias setting is initially set to the MGT number of the GTZ transceiver, but can
be changed by selecting the field and typing in a new value.
The Tile Location setting denotes the X/Y coordinate of the GTZ transceiver in the device.
The MGT Link Status indicator is displays the status of the link detection logic that is