100 
P5-34.0=1    input terminal is SI1 
P5-34.2=3    basic filtering time is 3ms 
P5-18=10      filtering time multiple is 10 
So the total filtering time is P5-34.2 * P5-18=3ms*10=30ms 
5.7.4.2 Output terminal distribution 
1. Output signal distribution 
n. 0   
Distribute output 
terminal no.
0: NO signal 
1: NC signal
No meaning
No meaning
Not distribute to terminal input 
Output  always  open  signal  from 
SOx 
Set the signal to be always valid 
output  always  close  signal  from 
SOx 
2. Default setting of output terminal   
 
5.7.5 Output terminal function 
5.7.5.1 Servo ready output (/S-RDY) 
  Related parameter 
/S-RDY: output 
condition selection 
 
Refer to section 3.2.2 for hardware wiring details.   
P5-41 parameter setting range is n.0000-0014, which is assigned to other output terminals through 
parameters. 
If it is necessary to output signal from SO2, P5-41 can be set to n.0002/0012. 
 
Servo ready signal output conditions 
When P5-70 is set to 0: after the driver initialization is completed and the servo has no alarm status 
/S-RDY is valid; 
When P5-70 is set to 1: after enabling, the servo has no alarm status /S-RDY is valid. 
5.7.5.2 Rotating detection output (/TGON) 
1. Signal setting 
Rotating detection 
output 
It is the output signal indicating that the servo motor is rotating at a speed higher than the set value. 
1.  No  terminal  output  signal is  assigned  by default.  The  parameter  range  is 0000-0018,  which  is