5.3.3.6 Set segment thorugh communication 
Set the segment 
number through 
communication 
If this parameter is set to a certain segment number, this segment position will be executed without 
step change signal. Communication can be used to modify parameters. 
For example: to execute the second segment position, set F2-09 = 0, and then F2-09 = 02. 
5.3.3.7 Motion start signal (/MRUN) 
Terminal  output  is  not 
assigned by default. 
It is only valid in the internal 
position  mode,  similar  to  the 
positioning  completion  signal 
in  the  external  pulse  mode; 
there is output when the motor 
is  running,  and  there  is  no 
output when the motor stops. 
Parameter  range  0000-0018, 
assigned to the output interface 
through parameter P5-50. When 
it  is  set  to  0001,  the  signal  is 
output from SO1 terminal. 
 
 
 
 
5.4 Speed control 
5.4.1 Speed mode general control 
5.4.1.1 Soft start 
Soft Start 
Acceleration Time 
Soft Start 
deceleration Time 
Soft start acceleration and deceleration time is suitable for mode 3/4/7. Smooth speed control can be 
carried out when step speed instruction is input or internal setting speed is selected. 
P3-09: Time from stop to rated speed 
P3-10: Time from rated speed to stop 
Target speed
Rated speed
Speed up time
P3-09
Speed down 
time
P3-10