145 
P2-69 = n.1000 P2-77 = 328 
 
Note: In both adaptive and auto-tuning modes, if mechanical characteristic analysis is used, the notch 
can be set manually. If there are multiple resonance points, the third to fifth notch can be configured in 
turn. 
 
 
6.7.5 Vibration suppression (manual setting) 
If the  resonance frequency of  the mechanical system  is known, the  vibration  can be  eliminated  by 
setting  the  vibration  frequency  manually.  Please  configure  the  third  to  fifth  notches.  The  related 
parameters are detailed in 6.7.7 notch filter. 
6.7.6 Vibration suppression (quick FFT) 
This function can  analyze the  mechanical characteristics  through the  parameter  F0-12 on  the servo 
operate panel, find out the mechanical resonance frequency and realize the vibration suppression. 
The complete operation process is shown in the figure below: 
Long press 
ENTER
Press 
ENTER
Press INC/DEC
Long press 
ENTER
Press 
ENTER
Find frequency 
successful
Long press ENTER
Write in successful
Wait for enable
Set torque
Enable status
 
The operation steps are described as follows: 
1. F0-12, long press【ENTER】to enter quick FFT function, it will show “E_FFt”. 
 
2. Press 【ENTER】  to enter torque setting interface, it will show the current setting torque, which 
is the value of  P6-89. Press【INC】,【DEC】to increase or decrease torque command. When 
increasing  the  torque  command,  it  is  recommended  to  increase  it  a  little  bit  to  avoid  severe 
vibration of the equipment. 
 
3. After setting the torque command, long press【ENTER】, enter “read to enable” status, it will 
show ‘F”.   
 
 4. Press【ENTER】, enable, it will show “..run”. 
 
5. Press【INC】,【DEC】  to run forward or reverse and find the resonance frequency. “E_FFt” will 
shining on the panel when operation. If the resonance frequency is found, it will show “Fxxxx”, 
“xxxx” is the resonance frequency. If failed, it will show “F----”. 
 
6. Whatever it shown “Fxxxx” or “F----”, press【INC】,【DEC】  can find the resonance frequency 
again. If the resonance frequency is found, long press【ENTER】to set the resonance frequency in 
the notch filter of servo driver.