188 
Appendix 4. Modbus address list 
Modbus  address  is  added  1  in  turn  from  0x0000,  for 
example, Modbus address of P0-23 is 0x0017 
Modbus  address  is  added  1  in  turn  from  0x0100,  for 
example, Modbus address of P1-10 is 0x010A 
Modbus  address  is  added  1  in  turn  from  0x020F,  for 
example, Modbus address of P2-16 is 0x0210 
Modbus  address  is  added  1  in  turn  from  0x0300,  for 
example, Modbus address of P3-13 is 0x030D 
Modbus  address  is  added  1  in  turn  from  0x0400,  for 
example, Modbus address of P4-25 is 0x0419 
Modbus  address  is  added  1  in  turn  from  0x0500,  for 
example, Modbus address of P5-20 is 0x0514 
Modbus  address  is  added  1  in  turn  from  0x0600,  for 
example, Modbus address of P6-05 is 0x0605 
Modbus  address  is  added  1  in  turn  from  0x0700,  for 
example, Modbus address of P7-11 is 0x070B 
Modbus  address  is  added  1  in  turn  from  0x1000,  for 
example, Modbus address of U0-05 is 0x1005 
Modbus  address  is  added  1  in  turn  from  0x1100,  for 
example, Modbus address of U1-14 is 0x110E 
Modbus  address  is  added  1  in  turn  from  0x1200,  for 
example, Modbus address of U2-08 is 0x1208 
 
Modbus  address  is  added  1  in  turn  from  0x1400,  for 
example, Modbus address of U4-11 is 0x120B 
Modbus  address  is  added  1  in  turn  from  0x2000,  for 
example, Modbus address of F0-01 is 0x2001 
Modbus  address  is  added  1  in  turn  from  0x2100,  for 
example, Modbus address of F1-03 is 0x2103 
Note: if the following parameters are not involved in the Modbus address table, follow the address rules 
in the table above. 
 
  Group P parameter address