Alarm List
Alarm Number (4000 to 4999)
Alarm List-789
4523 SHARED AXES
CONTROL ERROR
1 The teaching points are
incorrect.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
4524 CANNOT EXECUTE
INST(CONCUR JOB)
Setting error (1)Check the following settings.
∙ Delete an instruction that cannot be executed such as move
instruction in the concurrent job.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4525 CANNOT EXECUTE
SPECIFIED JOB
1 An interrupt job (user setting)
is started up during the back
operation.
Setting error (1)Check the following settings.
∙Check the job so that the interrupt job will not start-up during the back
operation.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
2 An suspend macro job is
started up during the back
operation.
Setting error (1)Check the following settings.
∙ Check the job so that the suspend macro job will not start-up during
the back operation.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
3 An interrupt job (inside the
system) is started up during
the back operation.
Setting error (1)Check the following settings.
∙Check the job so that the interrupt job will not start-up during the back
operation.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4527 UNDEFINED PORT
NO.(AOUT)
Setting error (1)Check the following settings.
∙ Check the settings for the specified analog output port number.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy