Alarm List
Alarm Number (4000 to 4999)
Alarm List-756
4464 OVER BCD RANGE Setting error (1)Check the following settings.
Correct the BCD data so that it is within the limit.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4465 OVER BINARY
RANGE
(PARITY CHECK)
Setting error (1)Check the following settings.
Correct the binary data so that it is within the limit.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4466 OFFLINE
UNDEFINED
COMMAND (ARITH)
0 An undefined command was
issued to the offline position-
data preparation section.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
4467 USER COORD STEP
NOT ENOUGH
Setting error (1)Check the following settings.
Correct the JOB that the number of steps will be three or more.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4468 ROBOT
CALIBRATION DATA
ERROR
1 The calibration between
manipulators cannot be
executed for this model.
Setting error (1)Check the following settings.
Do not use a coordinated motion with this manipulator.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
2 The master group and the
slave group are set to the
same group.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
3 Incorrect designation of the
control group for master group
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy