9Error
9.1 Error Message
9-13
9.1.4 External Memory Equipment
Error No. Data Error Message Contents
3010 - Floppy disk drive cable not connected
3020 - Floppy disk not inserted into floppy
disk drive
3021 - CompactFlash not inserted into
CompactFlash slot(PP)
3022 - USB media not inserted
3030 - Floppy disk protection is ON
3040 - File not saved on the media
3050 - File saved on the media
3060 - Out of memory on the media
3070 - Number of files on the media
3080 - I/O error on the media
3090 * Transmission error with the media
1 Framing error
2 Overrun error
3 Parity error
4 Data code error
5 Data read error
6 Data write error
7 Data time out
8 Serial I/O error
9 Error other than described above
3100 - Total checksum error When the security is in management mode or
safety mode, the CMOS.BIN file saved with
other controllers can not be loaded.
The memory size incorporated in the JZNCD-
YIF01-E board is different from the memory
size of the JZNCD-YIF01-E board used when
saved the CMOS.BIN file.
The CMOS.BIN file is broken or not be saved
properly.
3110 - Syntax error
3120 * HEX code error
1 Specification error of data decode
2 Specification error of EOF record
3 Record type error